Product Watch
Stat Diagnostics
Heliprobe
Since
Barry Marshall described the Helicobacter pylori (Hpylori) and its role in different
gastrointestinal diseases, an intense research effort has developed different
diagnostic methods. The only non-invasive test method that can be clinically
used as a diagnostic tool for on-going infection with H pylori and post-eradication
follow-up is the 'urea breath test'. Different serological tests are available,
but they cannot determine the actual status of the infection and can therefore
only be used for screening tests. With the Radprobe, a cost-effective test is
available, easy to use in the doctor's office.
How does Heliprobe work?
The Urea Breath Test method (UBT) is based on the fact that the bacteria H pylori
produces an enzyme, urease, which catalyes the hydrolysis of the urea molecule
into ammonium and carbon dioxide. H plyori requires the alkaline ammonium in
order to establish an optimal local mucosal environment within the acidic environment
of the stomach. The urea compound is an endogenous substance that contains one
carbon atom, normally C, which can be replaced by its isotope C or C. Heliprobe
uses the isotope C which has very low B-radioactive emission. The radioactive
dose used for a Heliprobe test is 1 uCurie, which is significantly less than
the radioactive dose given at a normal X-ray examination of the stomach, and
equal to a few glasses of orange juice.
A Helicap is ingested with 50 ml of water. If an infection with H pylori is
present in the stomach, the 'living' bacteria produces the enzyme 'urease' that
metabolises the C-urea into ammonium and carbon dioxide containing the C-labelled
atoms. The carbon dioxide will be assimilated through the mucosa into the blood
stream and transported to the lungs where it is exhaled. By collecting the exhaled
carbon dioxide in the BreathCard, the amount of CO2 produced in the stomach
can be measured with the Heliprobe TM instrument. If the patient is not infected,
no metabolisation of urea will occur and therefore no CO2 can be detected with
the Heliprobe system. In this case, the unmetabolised C urea will pass along
the digestive canal to be excreted in the urine. If the Heliprobe system detects
CO2, this is diagnostic evidence of an ongoing infection with living H pylori.
Heliprobe is developed for primary diagnosis of H pylori, as well as for follow-up
after eradication treatment.
Laboratory & Clinical Evaluation
To ensure equivalent results comparable with sophisticated, well-established
laboratory techniques used for scientific purposes, the following comparison
between Heliprobe and liquid scintillation for C detection was made. A laboratory
set-up (simulating the patient) with controlled parameters was established.
The result of the comparison was statistically analysed applying linear regression.
The outcome of the analysis shows a regression line with high correlation between
these methods. Clinical validation studies involving more than 400 patients
has also been performed at the Karolinska University Hospital in Stockholm,
Sweden.
CONTACT:
Stat Diagnostics Services
3rd Floor, Chandrapushpa Building
Opposite New Post Office
Hirachand Desai Marg
Ghatkopar (West)
Mumbai-86
Tel: 91-22-25112424
91-22-25157206
Ypsomed India
Clickfine
Ypsomed
India Private Limited has introduced Clickfine - a universal pen needle which
fits in all major injection pens (Self-Injecting devices)
Features:
Clickfine pen needles are with unique click feature. They come in a size of
6mm (31 G X1/4"). These needles fits in all major brands of insulin, growth
hormone and other self-injecting devices clickfine needle triple faceting needle
bevel cut and quick and easy removal of the sealing foil, patented click technology,
easy to twist off after injection and strong hold thanks to 5x2 snappers makes
it user friendly. These needles are single use devices. These are available
in the packet of five and packet of 10 needles. These are manufactured in Switzerland
by Ypsomed AG.
CONTACT:
Ypsomed India Private Limited
335, Udyog Vihar, Phase- IV
Gurgaon -122015
Tel: 91 999 99 75 1 57
Email: india_info_editor@ypsomed.com
india_editor@ypsomed.com
Nice Orchid 3000
Transport Baby Incubator
The
Nice Orchid 3000 - Transport Baby Incubator is a microprocessor controlled system
with air and skin modes of operation, with the following features:
- Displays air/skin temperature simultaneously with
set temperature.
- Feather-touch operation with large digital display
and comprehensive alarms.
- Memory backup to restore set temperature and control
mode automatically in the event of power failure.
- An integral and with drawable baby tray to aid resuscitation
during transport.
- An integral humidifier.
- Internal battery backup for four hours minimum. Operates
both on AC and DC currents, with visual indication for battery power status
and power sources.
- Collapsible stainless steel stand with shock absorbers.
- Dual thermistor temperature probes, with accuracy
of +0.2°C, to minimise down time and ensure accuracy. Probe interchangeable
without calibration. lA, 2D (or) 2E tank mounting facility to mount gas cylinders.
- Unimpeded access to the patient with frontal access
and a minimum of two access ports and three elbow operated ports.
- Easy to clean and disinfect.
- High intensity CFL Light for observation.
- Comprehensive alarms and safety features.
- O2 driven venturi slow suction with humidified O2.
- Accessories include: 'A' type cylinder, pressure
regulator assembly, IV stand, auxiliary tray shelf for other placing additional
equipment. Flow meter, O2 cylinder, O2 failure alarm.
CONTACT:
Nice Neotech Medical Systems Private Limited
85-86, Krishna Industrial Estate
Vannagaram, Mettukuppam
Chennai 600 095
Tel: 044-24764608 Fax: 044-24762594
Email: marketing@niceneotech.com
Website: www.niceneotech.com
Robonik (India)
Prietest eXP: Automatic Biochemistry Analyser
After
having established state-of-art infrastructure to manufacture medical diagnostic
instruments that meets quality of international standards and yet competitively
priced, Robonik introduces new model prietest eXP in biochemistry analyser range.
Prietest eXP is based on embedded technology which provides extended performance.
It has built in power supply with stabiliser, large size colour LCD, TFT, thermal
printer, dry block incubator.
Features:
- Operation is very easy by click of mouse or keyboard.
- Test assignment: Easy to program, Count for number
of samples, blank, QC samples, standards run. Complete reagent inventory management
with tracking of expiry date. Profile creation by laboratory.
- On line reaction graph in fixed time and kinetic
tests. Prompts the user validation of test.
- Absorbance measurement is done every second for complete
duration of reaction and data is stored in memory.
- Hyperactive enzyme assay is recalculated by automatic
search of linear portion of reaction in delay or read time interval.
- Automatic air purging between two samples minimises
the cross contamination.
- Quality Control for two different levels: 50 days
data with levey- Jennings Graph. lPatient assignment with complete data of
patient name, PID, sex, age, contact, name of doctor who referred helps the
operator to get report generation at the end of analysis. This avoids multiple
manual entry saves time and eliminates manual error in data entry. Avoids
paperwork.
- Report Generation: On normal A4 paper with complete
patient demography, laboratory logo, laboratory name and address, collated
sample result with edition of test results obtained through other means/ equipment.
- Large size memory: 250 user definable tests, 25,000
test results and two level QC for 30 days cumulative.
- The data can be imported and exported by pen drive.
CONTACT:
Robonik (India) Private Limited
Plot No A-374, TTC
MIDC Industrial Area
Mahape, Navi Mumbai - 400710
Tel: 022- 27780135 (5 lines)
Fax: 022- 27780145
Email: sales@robonikindia.com
marketing@robonikindia.com
Website: www.robonikindia.com
Schiller India
Defigard 400 Multi-Pulse Biphasic Defibrillator
Schiller
India, a leading Swiss joint venture company in the field of medical diagnostics,
has launched a new defibrillator called Defigard 400, India's first indigenously
manufactured multi-pulse Biphasic Defibrillator. According to V Balakrishnan,
Vice President, Sales, "The Indian market is shifting from monophasic to
biphasic defibrillators and in keeping with our goal to offer our customers
the latest technology at an affordable price, Schiller has introduced its Defigard
400 Defibrillator. The Defigard 400 Defibrillator uses Schiller's patented and
highly successful, multi-pulse biphasic current. This technology is widely preferred
in the advance market as it results inlower tissue damage to the patient's heart
and facilitates faster recovery."
Features of Defigard 400
- Large 6.4" colour TFT screen.
- Suitable for adult and paediatric application.
- Multi-pulse biowave technology for external defibrillation.
Selectable from 1 to 180J.
- Visual instructions and simple three steps operation.
- Three channel memory.
- 24 hours ECG. Last 11 shocks data saved.
- Trim knob and direct function keys for print, mute
and freeze.
- Digital out for ECG data to central monitoring station
- Integrated thermal printer with auto and manual modes
(optional).
CONTACT:
Hansa Soneji
Product Specialist
Schiller Healthcare India Private Limited
DC Silk Mills Compound
Kondivitta Lane
Andheri East
Mumbai - 400 059
Tel: 022 6692 0520
Fax: 022 2826 3525
Email: hansa@schillerindia.com
|