Products
Transasia Bio-Medicals
VES-MATIC 20
A Revolution in ESR Estimation
ESR
estimation has undergone little change since its incorporation in 1918 in standard
laboratory diagnosis. The renowned scientist Fahreus had discovered that erythrocytes
of pregnant women sedimented in plasma more rapidly than in non-pregnant women.
However, ESR estimation is still being performed by traditional methods and
is beset with a lot of drawbacks.
Transasia Bio-Medicals Ltd has addressed the issue with their Vesmatic 20 -
Fully Automated ESR Analyser - manufactured DIESSE DIAGNOSTICA, Italy. Ves-matic
20 correlates the ESR estimation with Westergren reference methods. The advanced
features and aesthetic looks make Ves-matic 20 a sure shot winner and deserves
a place in the laboratory.
Features:
- True walk away automation in ESR estimation.
- Throughput 60 samples/hr.
- Automated mixing of samples.
- Infra red sensor to inhibit interferences from lipid
and bilirubin.
- Temperature corrections to 18 degree C.
- Analysis by sedimentation kinetics.
- Sedimentation analysis in 20 minutes.
- Plastic evacuated tube - VACU-TEC prefilled with
sodium citrate.
- Only 1 ml of blood sample required.
- Absolute safe analysis.
- Readings perfectly correlated with westergren 1
hr and 2 hr reference methods
- Inbuilt printer.
For details contact:
Tel- 022- 2857 5050/ 022-2857 4040
Fax- 022- 2857 3030
Toll Free- 1901 222221
Bird Meditech
Microcomputer based Temperature Controller
Features:
- PID (proportionate integrated derivative) based
micro processor technology assures accurate maintenance of set temperature
with internal accuracy of 0.01°C
- Watch Dog facility Auto-Resets the System during
hang-ups due to power fluctuation
- User Friendly feather touch key operated DIGITAL
ON-BOARD calibration. Even a nurse can calibrate the system without opening
the machine.
- Voice Messaging Alarm Technology
- Separate display of actual, set temperature &
numerical display of heater power output
- Alarm systems both visual & audio (with audio
mute facility): Over temp. (>38oC), Under temp. (<34oC), Low temp.,
High temp., Probe failure & Power failure.
- Manual mode with Programmable time duration, Over
temp. cut off during manual mode, Heater power control possible in manual
mode. In case of sensor failure, manual mode provides moderate heating.
- Inbuilt timer and stopwatch.
- Control temp. range: Body temp to 38oC. Safety cut
off at 38oC
- INFRARED CERAMIC HEATER (650 watts) with stainless
steel reflector.
- Swiveling Heater box with Halogen examination lamp
(230V).
- Power source: 230 volts +/- 10%, 50 Hz.
- Fabrication available in Mild Steel / Stainless
steel with Stainless steel baby tray
- Acrylic collapsible side panels to access infant
from all sides.
- Acrylic baby tray with Head up/down facility with
thick cushion mattress
- Lower shelf to keep essential things for baby
- Instrument tray, IV stand, Clamp for infusion pump
Available
Controllers: Air/Manual, Skin/Manual & Skin/Air/Manual (with LCD)
Available Models: Stand, Stand with Trolley, Fixed
Cradle, Fixed Cradle with Under Surface Phototherapy/Double Surface Phototherapy,
Wall Mounting, Resuscitation System
Other Products: Phototherapy Systems, Oxygen Hood,
Digital Weighing Scales, Pulse Oximeter, Infusion Pump, Resuscitation bags /
kits etc.
For details contact:
Vijay Parmar (9234001836)/
Deepak Patel (9324380517)
Bird Meditech An ISO 9001:2000 Certified Company
D-143, Jai Bonanza Indl. Estate,
Ashok Chakravarty Road,
Kandivli (East),
Mumbai - 400 101, INDIA
Tel: 91-22-32946679
Fax: 91-22-28877583
Email: birdmeditech@sify.com
Website: www.birdmeditech.com
Dhansai Laboratory
PRADIP Pad a Solace for Diabetic Foot
After
the advent of Sensitometer-VPT by Dhansai Laboratory the spectrum
of Diabetic Sensory Polyneuropathy became evident. The people with high risk
of ulceration remained vulnerable. As the motor neuropathy alters the shape
of the foot, plantar surface develops high-pressure areas. These pressures can
be as high as 1500 kilo Pascal. This is nearly 15 times atmospheric pressure.
These high pressures literally crush the tissue between the bone and the skin
under it. The person with an insensate foot doesnt realize it and in time
develops an ulcer there.
But measurement of these high pressure points and then customizing the footwear
by redistribution of pressure remained a big problem. The traditional Harris
mat used for leprosy patients, was highly inadequate as it gives only qualitative
information and has a limited range measurable. That is to say it cannot read
above 250 to 300 hundred Kilo Pascal. And bellow 300 Kilo Pascal even barefoot
walking wont develop injury. The newer variants lacks even in qualitative
information due to poor resolution. And the high-end foot scanners are not economically
viable in smaller cities and district levels. The PRADIP Pad invented
by D K Kelkar, chief scientist from DHANSAI Laboratory provided
the solution. It has the high resolution of 645 points per square inch, which
is the highest world over. It gives both qualitative and quantitative information.
As it is devised essentially for persons with diabetes, a unique system of disbursement
of customized footwear is developed around it. This economical pad can be used
even at village level and the foot impressions are sent to companys Mumbai
hub via E-Mail or Post. The impression can be taken by a technician and will
be analyzed by an expert, so it does not burden the physician. The experts at
the hub process and analyze the same and send back a report by the same route.
Thec clinician can show the same to the person concerned and order customized
footwear.
For details contact:
Dhansai Laboratory
3B, Uttung, Samant Wadi, off Sonawala Road,
Goregaon (East), Mumbai 400 063
022 2686371, Mo 09819526756
Email: dhansai@vsnl.com
Trivitron
Capillarys2
Sebia,
France, exclusively focussed on Electrophoresis Products, has designed and developed
the latest model based on capillary action called the Capillarys2, which is
a fully automated system with walk away capability. Capillarys2 uses eight position
capillary tubes, each filled with electrolyte buffers for the reactions, and
can provide a high throughput of upto 90 protein samples per hour. The first
Capillarys2 system was installed at Anand Institute of Lab Medicine, Bangalore
in March 2006.
Features include:
- Menus for testing Proteins (with no lipid interference)
- Hemoglobin Electrophoresis
- Immunotyping (an automated alternative to Immuno
fixation testing)
- HR (High Resolution Protein separation)
- CDT (Carbohydrate - Deficient Transferring) to detect
alcohol abuse and haemoglobin.
- Complete reagent traceability
- A sophisticated and interpretive software facilitating
easy reporting
- A stable and long lasting Deuterium lamp light source
- Continuous loading of samples
- A built-in QC program
- Host communication and results transfer through
modems & flexible reporting options.
HbA1c detection will be available very soon.
New Erbe Cardiac Diathermy - VIO 300S
The
VIO 300S is a Modular Diathermy for Cardiac OT with twin coagulation modes.
Two monopolar handpieces can be used simultaneously - a key requirement for
bypass surgeries. The VIO 300S has broken the monopoly of the ValleyLab diathermy
in the cardiac segment.
The features include:
- Automatic Output Dosage
- New and improved CUT and COAG functions, both monopolar
and bipolar
- Can be individually configured to meet requirements
of different medical specialties, indications and procedures.
For details contact:
Trivitron,
15, IV ST, Abhiramapuram,
Chennai - 18
Tel: 91-44-24985050
Fax: 91-44-24985757/24672782
Website:www.trivitron.com
|